Circular No. 19/2023/TT-BCT dated November 01, 2023 of the Ministry of Industry and Trade on providing method to build electricity generation price brackets applicable to solar power plants and wind power plants
Issuing body: Ministry of Industry and TradeEffective date:
Known

Please log in to a subscriber account to use this function.

Don’t have an account? Register here

Official number:19/2023/TT-BCTSigner:Nguyen Sinh Nhat Tan
Type:CircularExpiry date:Updating
Issuing date:01/11/2023Effect status:
Known

Please log in to a subscriber account to use this function.

Don’t have an account? Register here

Fields:Commerce - Advertising , Electricity , Industry

SUMMARY

Principles for building the electricity generation price bracket of solar power plants and wind power plants

On November 01, 2023, the Ministry of Industry and Trade issuses Circular No. 19/2023/TT-BCT on providing method to build electricity generation price brackets applicable to solar power plants and wind power plants. Accordingly, the electricity generation price brackets applicable to solar power plants and wind power plants plants are built based on the following principles:

1. Electricity generation price bracket of ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants, offshore wind power plants is a value range from the minimum value (0 VND/kWh) to the maximum value, established and issued annually.

2. The maximum value applicable to solar power plants is the electricity generation price of a standard solar power plant that is determined by the following methods:

  • Method to determine electricity generation prices of standard solar power plants.
  • Method to determine the average fixed prices of standard solar power plants.
  • Method to determine the fixed operation and maintenance prices of standard solar power plants.

3. The maximum value applicable to wind power plants is the electricity generation price of a standard wind power plant that is determined by the following methods:

  • Method to determine electricity generation prices of standard wind power plants.
  • Method to determine the average fixed prices of standard wind power plants.
  • Method to determine the fixed operating and maintenance prices of standard wind power plants.

4. The electricity generation price bracket for ground-mounted solar power plants and floating solar power plants should be based on the average annual radiation intensity of the three regions: North, Central and South.

5. A standard solar power plant is selected to build an electricity generation price bracket according to the regions: North, Central and South.
This Circular takes effect from December 19, 2023.
For more details, click here.
Download files here.
LuatVietnam.vn is the SOLE distributor of English translations of Official Gazette published by the Vietnam News Agency
Effect status: Known

THE MINISTRY OF

INDUSTRY AND TRADE
__________________

No. 19/2023/TT-BCT

THE SOCIALIST REPUBLIC OF VIETNAM
Independence - Freedom - Happiness

_______________________

Hanoi, November 01, 2023

 

CIRCULAR

On providing method to build electricity generation price brackets applicable to solar power plants and wind power plants

___________________________

 

Pursuant to the Government’s Decree No. 96/2022/ND-CP dated November 29, 2022, defining the functions, tasks, powers and organizational structure of the Ministry of Industry and Trade;

Pursuant to the Government’s Decree No. 137/2013/ND-CP dated October 21, 2013, on detailing a number of articles of the Electricity Law and the Law Amending and Supplementing a Number of Articles of the Electricity Law;

At the proposal of the Director of the Electricity Regulatory Authority of Vietnam;

The Minister of Industry and Trade promulgates the Circular providing methods to build electricity generation price brackets applicable to solar power plants and wind power plants.

 

Chapter I

GENERAL PROVISIONS

 

Article 1. Scope of regulation and subjects of application

1. This Circular provides regulations on:

a) Method to build annual electricity generation price brackets for ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants, offshore wind power plants;

b) Procedure for building and promulgating the annual electricity generation price brackets.

2. This Circular does not apply to solar power plants, wind power plants specified at Point b Clause 2 Article 1 of the Minister of Industry and Trade’s Circular No. 15/2022/TT-BCT dated October 3, 2022, promulgating the method of building the electricity generation price bracket applicable to transitional solar power plants, wind power plants, and solar power plants, wind power plants that have power purchase agreements signed with Vietnam Electricity with valid electricity prices.

3. This Circular applies to the following subjects:

a) Vietnam Electricity (EVN);

b) Organizations and individuals participating in investing in solar power plants, wind power plants;

c) Other related organizations and individuals.

Article 2. Interpretation of terms

In this Circular, the terms below are construed as follows:

1. A standard solar power plant means a solar power plant of which the investor is selected on the basis of implementing the National Power Development Plan, with a popular capacity scale, and an unsigned power purchase contract. Such power plant represents the type of ground-mounted solar power plant and floating solar power plant and is used to calculate the electricity generation price bracket for that type of power plant.

2. A floating solar power plant means a grid-connected solar power plant with photovoltaic panels mounted on a floating structure.

3. A ground-mounted solar power plant means a grid-connected solar power plant other than those specified in Clause 2 of this Article.

4. A standard wind power plant means a wind power plant of which the investor is selected on the basis of implementing the National Electricity Development Plan, with a popular capacity scale, and an unsigned power purchase contract. Such power plant represents the type of onshore wind power plant, nearshore wind power plant, offshore wind power plant and is used to calculate the electricity generation price bracket for that type of power plant.

5. An onshore wind power plant means a grid-connected wind power plant with the center of the wind turbine foundation built and operating within the shoreline of the lowest average sea level in many years on the mainland under current regulations.

6. A nearshore wind power plant means a grid-connected wind power plant with the center of the wind turbine foundation built and operating within the boundary between the shoreline of the lowest average sea level in many years on the mainland under current regulations, and the line 06 nautical miles away from the shoreline of the lowest average sea level in many years on the mainland.

7.  An offshore wind power plant means a grid-connected wind power plant with the wind turbines built outside the 6-nautical mile sea region of the mainland.

8. Total investment means the entire construction investment cost of a project that is determined according to current legal regulations and suitable with the basic design and other contents of the construction investment feasibility study report.

 

Chapter II

METHOD TO DETERMINE THE ELECTRICITY GENERATION PRICE BRACKET

 

Article 3. Principles for building the electricity generation price bracket

1. Electricity generation price bracket of ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants, offshore wind power plants is a value range from the minimum value (0 VND/kWh) to the maximum value, established and issued annually.

2. The maximum value applicable to solar power plants is the electricity generation price of a standard solar power plant that is determined according to the method specified in Articles 4, 5 and 6 of this Circular.

3. The maximum value applicable to wind power plants is the electricity generation price of a standard wind power plant that is determined according to the method specified in Articles 7, 8 and 9 of this Circular.

4. The electricity generation price bracket for ground-mounted solar power plants and floating solar power plants should be based on the average annual radiation intensity of the three regions: North, Central and South.

5. A standard solar power plant is selected to build an electricity generation price bracket according to the regions specified in Clause 4 of this Article.

Article 4. Method to determine electricity generation prices of standard solar power plants

Electricity generation prices  (VND/kWh) of standard solar power plants shall be determined according to the following formula:

= FCMT + FOMCMT

In which:

FCMT:

Average fixed prices of standard solar power plants, determined under Article 5 of this Circular (VND/kWh);

FOMCMT:

Fixed operation and maintenance prices of standard solar power plants, determined under Article 6 of this Circular (VND/kWh).

Article 5. Method to determine the average fixed prices of standard solar power plants

1. Average fixed prices FCMT (VND/kWh) of standard solar power plants are the components to recover investment costs, determined according to the following formula:

In which:

TCMT:

Cost of capital investment to build the standard solar power plant (excluding value-added tax), converted annually and determined under Clause 2 of this Article (VND);

Delivered average electric power over many years of the standard solar power plant, determined under Clause 5 of this Article (kWh).

2. Cost of capital investment of the standard solar power plant is converted annually TCMT (VND) according to the following formula:

In which:

SĐTMT:

Construction unit cost of the standard solar power plant, determined under Clause 3 of this Article (VND/kWp), of which kWp is the unit of measurement for the peak power achieved by solar photovoltaic panels under standard conditions;

PMT:

Installed capacity of the standard solar power plant specified in Clause 1 Article 2 of this Circular (kWp);

nMT:

The economic life of the standard solar power plant specified in the Appendix to this Circular (year);

i:

The financial discount rate of the standard solar power plant, determined under Clause 4 of this Article (%).

3. Construction unit cost is the investment cost for 01 kWp of installed capacity of the standard solar power plant (excluding investment costs for lines and transformer stations to the connection point, energy storage system), determined on the basis of total effective investment, updated foreign exchange rates at the time of calculating the electricity generation price brackets, referred to data from consulting organizations (if necessary).

4. The financial discount rate i (%) applying the nominal pre-tax weighted average cost of capital of the standard solar power plant shall be determined according to the following formula:

In which:

D:

Proportion of loan capital in the total investment, specified in the Appendix issued with this Circular (%);

E:

Owner's capital contribution ratio in the total investment, specified in the Appendix issued with this Circular (%);

nMT:

The economic lifetime of the standard solar power plant, specified in the Appendix issued with this Circular (year);

nD:

Average loan repayment period, specified in the Appendix issued with this Circular (years);

rd:

Loan interest rate, determined under Point a of this Clause (%);

re:

Pre-tax profit margin on owner's capital contribution, determined under Point b of this Clause (%).

a) Loan interest rate rd (%) is calculated by the weighted average interest rate of domestic and foreign currency loans according to the following formula:

rd = DF x rd,F + DD x rd,D

In which:

DF:

Proportion of foreign currency loan in the total loan capital, specified in the Appendix issued with this Circular (%);

DD:

Proportion of domestic currency loan in the total loan capital, specified in the Appendix issued with this Circular (%);

rd,F:

Foreign currency loan interest rate, determined by the average interest rate SOFR (Secured Overnight Financing Rate) for an average term of 180 days (180 Days - Average) of the 36 months preceding the time of building the price bracket announced by the Fed (Website:  www.newyorkfed.org), plus the average annual rate of the bank's loan arrangement fees of 3%/year;

rd,D:

Domestic currency loan interest rate, determined by the average of the deposit interest rate in Vietnamese dong for a 12-month deferred payment term for individual customers of the 5 years preceding the year of construction of the price bracket, determined on September 30 every year of four commercial banks (Joint Stock Commercial Bank for Foreign Trade of Vietnam, Vietnam Joint Stock Commercial Bank for Industry and Trade, Joint Stock Commercial Bank for Investment and Development of Vietnam, Vietnam Bank for Agriculture and Rural Development or legal successor units of these banks), plus the average annual rate of bank service fees of 3.5% (%/year).

b) Pre-tax profit margin on owner's capital contribution re (%) is determined according to the following formula:

In which:

re,pt:

After-tax profit margin on owner's capital contribution (%), which is determined to be 12%;

t:

Average corporate income tax rate in the economic lifetime of the solar power plant, determined according to current regulations of the State (%).

5. The average annual delivered electric power  (kWh) of standard solar power plants is determined according to the following formula:

= A x r x H x PR

In which:

A:

Total installed area of photovoltaic panels (m2) corresponding to the installed capacity of standard solar power plants, determined in accordance withs Clause 6 of this Article;

H:

Average annual solar radiation intensity of the three regions: North, Central and South corresponding to standard solar power plants (kWh/m2/year);

r:

Photovoltaic panel conversion efficiency (%);

PR:

Efficiency of standard solar power plant (%).

6. The parameters A, r, H, PR specified in Clause 5 of this Article are determined on one of the following bases:

a) Feasibility study report or approved technical design of standard solar power plants;

b) Data of consulting organizations.

Article 6.  Method to determine the fixed operation and maintenance prices of standard solar power plants

1. Fixed operation and maintenance prices FOMCMT (VND/kWh) of standard solar power plants are the components to recover major repair costs, labor and other annual costs, determined according to the following formula:

In which:

Total fixed operation and maintenance cost of the standard solar power plant, determined under Clause 2 of this Article (VND).

Delivered average electric power over many years of the standard solar power plant, determined under Clause 5 Article 5 of this Circular (kWh).

2. The total fixed operation and maintenance cost (VND) of the standard solar power plant is determined according to the following formula:

= SĐTMT x PMT x kMT

In which:

SĐTMT:

Construction unit cost of the standard solar power plant, determined according to Clause 3 Article 5 of this Circular (VND/kWp);

PMT:

Installed capacity of the standard solar power plant specified in Clause 1 Article 2 of this Circular (kWp);

kMT:

Proportion of fixed operation and maintenance cost in the construction unit cost of the standard solar power plant, determined on the basis of consulting data of consulting organizations.

Article 7. Method to determine electricity generation prices of standard wind power plants

Electricity generation prices  (VND/kWh) of standard wind power plants shall be determined according to the following formula:

= FCG + FOMCG

In which:

FCG:

Average fixed prices of standard wind power plants, determined under Article 8 of this Circular (VND/kWh);

FOMCG:

Fixed operation and maintenance prices of standard wind power plants, determined under Article 9 of this Circular (VND/kWh).

Article 8. Method to determine the average fixed prices of standard wind power plants

1. Average fixed prices FCG (VND/kWh) of standard solar power plants are the components to recover investment costs, determined according to the following formula:

In which:

TCG:

Cost of capital investment to build the standard wind power plant (excluding value-added tax), converted annually and determined under Clause 2 of this Article (VND);

:

The delivered average electric power over many years of the standard wind power plant, determined under Clause 5 of this Article (kWh).

2. Cost of capital investments of standard wind power plants is converted annually TCG (VND) according to the following formula:

In which:

SĐTG:

Construction unit cost of the standard wind power plants, determined under Clause 3 of this Article (VND/kW);

PG:

Installed capacity of the standard wind power plant specified in Clause 4 Article 2 of this Circular (kW);

nG:

The economic lifetime of the standard wind power plant, specified in the Appendix issued with this Circular (year);

i:

The financial discount rate of the standard wind power plant, determined under Clause 4 of this Article (%).

3. Construction unit cost is the investment cost for 01 kWp of installed capacity of the standard wind power plant (excluding investment costs for lines and transformer stations to the connection point, energy storage system), determined on the basis of total effective investment, updated foreign exchange rates at the time of calculating the electricity generation price bracket, referred to data from consulting organizations (if necessary).

4. The financial discount rate i (%) applying the nominal pre-tax weighted average cost of capital for the standard wind power plant shall be determined by the following formula:

In which:

D:

Proportion of loan capital in the total investment, specified in the Appendix issued with this Circular (%);

E:

Owner's capital contribution ratio in the total investment, specified in the Appendix issued with this Circular (%);

nG:

The economic lifetime of the standard wind power plant, specified in the Appendix issued with this Circular (year);

nD:

Average loan repayment period specified in the Appendix issued with this Circular (year);

rd:

Loan interest rate, determined under Point a of this Clause (%);

re:

Pre-tax profit margin on owner's capital contribution, determined under Point b of this Clause (%).

a) Loan interest rate rd (%) is calculated by the weighted average interest rate of domestic and foreign currency loans according to the following formula:

rd = DF x rd,F + DD x rd,D

In which:

DF:

Proportion of foreign currency loan in the total loan capital, specified in the Appendix issued with this Circular (%);

DD:

Proportion of domestic currency loan in the total loan capital, specified in the Appendix issued with this Circular (%);

rd,F:

Foreign currency loan interest rate, determined by the average interest rate SOFR (Secured Overnight Financing Rate) for an average term of 180 days (180 Days - Average) of the 36 months preceding the year of construction of the price bracket announced by the Fed (Website:www.newyorkfed.org), pulsed the average annual rate of the bank's loan arrangement fees of 3%/year;

rd,D:

The domestic currency loan interest rate, determined by the average of the deposit interest rate in Vietnamese dong for a 12-month deferred payment term for individual customers of the 5 years preceding the year of construction of the price bracket, determined on September 30 every year of four commercial banks (Joint Stock Commercial Bank for Foreign Trade of Vietnam, Vietnam Joint Stock Commercial Bank for Industry and Trade, Joint Stock Commercial Bank for Investment and Development of Vietnam, Vietnam Bank for Agriculture and Rural Development or legal successor units of these banks), plus with the average annual rate of bank service fees of 3.5% (%/year).

b) Pre-tax profit margin on owner's capital contribution re (%) shall be determined according to the following formula:

In which:

re,pt:

After-tax profit margin on owner's capital contribution (%), which is determined to be 12%;

t:

Average corporate income tax rate in the economic lifetime of the wind power plant, determined according to current regulations of the State (%).

5. The average annual delivered electric power ( kWh) of the standard wind power plant shall be determined according to the following formula:

= EG,P50 - EG,P50 x kbd x kpb,P75

In which:

EG,P50:

Delivered average electric power over many years of the wind power plant is 50%, determined under Clause 6 of this Article (kWh).

kbd:

Total uncertainty level of standard wind power plant (%);

kpb,P75:

The normal distribution coefficient corresponding to the delivered average electric power over many years of the standard wind power plant is 75%, specified in the Appendix issued with this Circular.

6. The delivered average electric power over many years of the standard wind power plant is 50%, determined as follows (kWh):

EG,P50 = 8760 x PG x kCF

In which:

PG:

Installed capacity of the standard wind power plant specified in Clause 4 Article 2 of this Circular (kW);

kCF:

Capacity factor of the standard wind power plant (%);

7. The parameters kCF and kbd specified in Clause 5 and Clause 6 of this Article are determined on one of the following bases:

a) Feasibility study report or approved technical design of standard solar power plants;

b) Data of consulting organizations.

Article 9. Method to determine the fixed operating and maintenance prices of standard wind power plants

1. Fixed operation and maintenance prices FOMCG (VND/kWh) of standard wind power plants are the components to recover major repair costs, labor and other annual costs, determined according to the following formula:

In which:

Total fixed operation and maintenance cost of the standard wind power plant, determined under Clause 2 of this Article (VND).

Delivered average electric power over many years of the standard wind power plant, determined under Clause 5 Article 8 of this Circular (kWh).

2. Total fixed operation and maintenance costs (VND) of standard wind power plants shall be determined according to the following formula:

= SĐTG x PG x kG

In which:

SĐTG:

Construction unit cost of the standard wind power plant, determined under Clause 3 Article 8 of this Circular (VND/kW);

PG:

Installed capacity of the standard solar power plant (kW) specified in Clause 4 Article 2 of this Circular (kW);

kG:

Proportion of fixed operation and maintenance cost in the construction unit cost of the standard wind power plant, determined on the basis of referring to data from consulting organizations (%).

 

Chapter III

PROCEDURES FOR BUILDING AND PROMULGATING ELECTRICITY GENERATION PRICE BRACKET

 

Article 10. Procedures for building and promulgating electricity generation price bracket

1. Before November 1 of each year, EVN shall:

a) Propose the selection of standard solar power plants and standard wind power plants to calculate the electricity generation price bracket.

b) Calculate or hire consultants to select sets of parameters and calculate electricity generation prices of standard solar power plants and standard wind power plants according to Chapter II of this Circular.

c) Prepare a dossier for calculating the electricity generation price bracket of ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants and offshore wind power plants for the next year as prescribed in Article 11 of this Circular, and submit it to the Electricity Regulation Authority of Vietnam for appraisal.

2. Within 05 working days from the date of receipt of the dossier for calculating the electricity generation price bracket mentioned in Article 11 of this Circular, the Electricity Regulatory Authority of Vietnam shall inspect in detail the content of the dossier, the completeness and validity of the dossier submitted for approval. If necessary, the Electricity Regulatory Authority of Vietnam shall issue a written request to EVN to amend, supplement or clarify the contents of the dossier. No later than 15 working days from the date of receipt of the request for amendment, supplementation or clarification of the contents in the dossier of the Electricity Regulatory Authority of Vietnam, EVN shall send a written explanation report on the contents of the dossier as required.

3. In case of receipt of a valid dossier and a clarification report on the contents of the dossier of EVN, within 20 working days from the date of receipt of the dossier, the Electricity Regulatory Authority of Vietnam shall organize the appraisal of the electricity generation price bracket submitted by EVN.

If necessary, the Electricity Regulatory Authority of Vietnam shall collect opinions on the electricity generation price bracket through the Advisory Council established by the Ministry of Industry and Trade or the affected subjects. The Advisory Council consists of a maximum of 9 members, including 01 chairperson, 01 vice chairperson, 01 secretary, and representatives of relevant units of the Ministry of Industry and Trade with appropriate qualifications and comprehensive knowledge in the field of electricity generation.

4. No later than 15 working days from the date of appraisal of the electricity generation price bracket, the Electricity Regulatory Authority of Vietnam shall submit to the Minister of Industry and Trade for approval the electricity generation price bracket for the type of ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants and offshore wind power plants for the next year and publish it on the website of the Electricity Regulatory Authority of Vietnam. In case the electricity generation price bracket of the next year has not yet been announced, the latest effective electricity generation price bracket shall be temporarily applied.

Article 11. Dossier of request for approval of electricity generation price bracket

A dossier of request for approval of the electricity generation price bracket of a ground-mounted solar power plant, floating solar power plant, onshore wind power plant, nearshore wind power plant or offshore wind power plant comprises:

1. Proposal of EVN on the selection of parameters and calculation of electricity generation price bracket.

2. The parameter table and documents for calculating electricity generation prices for standard solar power plants and standard wind power plants in accordance with Chapter II and the Appendix issued together with this Circular.

3. Documents related to the parameters for calculating electricity generation prices.

 

Chapter IV

IMPLEMENTATION PROVISIONS

 

Article 12. Organization of implementation

1. The Electricity Regulatory Authority of Vietnam shall appraise the annual electricity generation price bracket and submit it to the Minister of Industry and Trade for approval.

2. If necessary, the Electricity Regulatory Authority of Vietnam shall rebuild the table of parameters used to calculate electricity generation prices for standard solar power plants and standard wind power plants specified in the Appendix to this Circular and report to the Ministry of Industry and Trade for consideration and decision.

3. EVN shall:

a) Select or hire consultants to select standard solar power plants, standard wind power plants.

b) Calculate or hire consultants to calculate the electricity generation price bracket for ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants and offshore wind power plants.

c) Submit to the Electricity Regulatory Authority of Vietnam the dossier for calculating the electricity generation price bracket for ground-mounted solar power plants, floating solar power plants, onshore wind power plants, nearshore wind power plants and offshore wind power plants in accordance with Article 10 and Article 11 of this Circular.

Article 13. Effect

1. This Circular takes effect from December 19, 2023.

2. In case the documents referred to in this Circular are amended, supplemented or replaced, the amending, supplementing or replacing ones shall prevail.

3. Any problems arising in the course of implementation of this Circular should be reported to the Ministry of Industry and Trade for appropriate amendment and supplementation./.

 

FOR THE MINISTER

DEPUTY MINISTER

 

 

Nguyen Sinh Nhat Tan

 

APPENDIX

PARAMETERS FOR CALCULATION OF ELECTRICITY GENERATION PRICE BRACKET

(Promulgated together with the Minister of Industry and Trade’s Circular No. 19/2023/TT-BCT dated November 01, 2023)

 

I. PARAMETERS FOR CALCULATION OF ELECTRICITY GENERATION PRICES OF STANDARD SOLAR POWER PLANTS AND STANDARD WIND POWER PLANTS

No.

Item

Symbol

Parameter

I

Economic lifetime

 

 

1

Standard solar power plant

nMT

20 years

2

Standard wind power plant

nG

20 years

II

Operating parameters

 

 

1

The normal distribution coefficient corresponding to the delivered average electric power energy over many years according to the expectation of 75% of the standard wind power plant

kpb,P75

0,674

III

The proportion of capital sources in the total investment capital of the solar power plant, standard wind power (%)

 

 

1

The proportion of loan capital

D

70%

2

The owner's capital contribution ratio

E

30%

3

The proportion of foreign currency loan

DF

80%

4

The proportion of domestic currency loan

DD

20%

IV

Average debt repayment period (year)

nD

10 years

II. KEY PARAMETERS OF STANDARD SOLAR POWER PLANTS AND STANDARD WIND POWER PLANTS

No.

Content

Symbol

Unit

I

The cost of annually converted capital investment construction

VND

1

The power plant’s construction unit cost

SĐTMT,G

VND/kWp or VND/kW

2

The power plant’s installed capacity

PMT, PG

kWp, kW

II

Economic lifetime

nMT, nG

Year

III

Annual average electric power at the delivery point

Ebq

kWh

1

Operational parameters (for calculation of average annual delivered electric power)

 

 

IV

Financial discount rates

i

%

1

Proportion of foreign currency loan

DF

%

2

Proportion of domestic currency loan

DD

%

3

Foreign currency loan interest rate

rd,F

%

4

Domestic currency loan interest rate

rd,D

%

3

Pre-tax profit margin

re

%

3.1

After-tax profit margin on owner's capital contribution

re,pt

%

3.2

Average corporate income tax rate in the economic lifetime

t

%

A

Average fixed prices

FC

VND/kWh

 

Total fixed operation and maintenance costs

TCFOMC

VND

B

Fixed operation and maintenance prices

FOMC

VND/kWh

C

Electricity generation prices (A+B)

VND/kWh

Please log in to a subscriber account to see the full text. Don’t have an account? Register here
Please log in to a subscriber account to see the full text. Don’t have an account? Register here
Processing, please wait...
LuatVietnam.vn is the SOLE distributor of English translations of Official Gazette published by the Vietnam News Agency

VIETNAMESE DOCUMENTS

Circular 19/2023/TT-BCT DOC (Word)

This utility is available to subscribers only. Please log in to a subscriber account to download. Don’t have an account? Register here

Circular 19/2023/TT-BCT PDF (Original)

This utility is available to subscribers only. Please log in to a subscriber account to download. Don’t have an account? Register here

ENGLISH DOCUMENTS

LuatVietnam's translation
Circular 19/2023/TT-BCT DOC (Word)

This utility is available to subscribers only. Please log in to a subscriber account to download. Don’t have an account? Register here

Circular 19/2023/TT-BCT PDF

This utility is available to subscribers only. Please log in to a subscriber account to download. Don’t have an account? Register here

* Note: To view documents downloaded from LuatVietnam.vn, please install DOC, DOCX and PDF file readers
For further support, please call 19006192

SAME CATEGORY

loading